Floor surface temperatures are critical for comfort, as well as to heat output otherwise discomfort and damage to the floor can occur. BS EN 1264 Floor Heating – Systems and Components, Part 2. Determination of thermal output provides some guidelines on the maximum values for floor surface temperatures. These are summarised below.
|
Area |
Maximum Floor Surface Temperature °C |
Design Room |
Corresponding Heat |
|
Occupied area |
29 |
20 |
100 |
|
Peripheral area |
35 |
20 |
175 |
|
Bathroom or similar |
33 |
24 |
100 |